WNWALL DOHA TESTING SERVICES 

WnWall Doha focused on Testing for building Envelopes, which includes: 

•    Curtain wall Doors & windows Testing as per ASTM, AAMA and BS EN  which are the most commonly                                         Standard world wide 
•    Fire Resistance Test as per NFPA Standard 
•    Insulated Glass Unit (IGU) Testing as per ASTM Standard 
•    Onsite Testing as per ASTM & AAMA Standards 

WNWALL Offers both testing in the Lab to check and validate the design of façade (Offsite Test) and Field Testing to check consistency of fabrication and installation (Onsite Test) 

WnWall Doha Performs the following tests for building envelops/components at our laboratory facility to the corresponding test specification  


OFFSITE (LAB) TESTS 

CURTAIN WALL, DOORS & WINDOWS 
•    Air Penetration Test (ASTM E283, BS EN 1026, BS EN 12153)   
•    Water Penetration Test (Static) (ASTM E331, BS EN 1027, BS EN 12155) 
•    Structural Performance Test (ASTM E330, BS EN 12179, BS EN 12211) 
•    Water penetration Test (Dynamic) (AAMA 501.1, BS EN 13050) 
•    Impact Tests (ASTM E2353, BS EN 12600) 
•    Pullout Test 
•    Seismic Racking Test (AAMA 501.4, AAMA 501.7) 
•    Thermal Cycling (AAMA 501.5) 
•    Controlled Dismantle  
HANDRAILS & BALLUSTRADE SYSTEM 
•    Balustrade Performance (ASTM E2353, ASTM E935)  
IGU TEST AND GLASS DISTORTION TEST  
•    Distortion (Rollerwave Test) BS EN 12150
•    Fragmentation Test (BS EN 12150) 
FIRE PROPOGATION
ANALYSIS OF GLASS BREAKAGE 
TECHNICAL SERVICES
 

ONSITE TESTS 

•    Thermal Performance of Buildings Determination of Air Permeability of  Buildings (EN 13829 – ISO 9972 (2015) )
•    Thermography Analysis 
•    Air Infiltration Test (ASTM E783) 
•    Water Penetration Test (ASTM E1105) 
•    Hose Test - Water Penetration Test (AAMA 501.2) 
•    Impact Test (ASTM E2353, BS EN 12600) 
•    Acoustic Test 
•    Climate parameters Monitoring 
•    Structural Sealant Adhesion Test (ASTM C1401) 

Contact Us

Qatar Office:

 

Address: Zone No: 74, Street No: 10,

Al Khor Industrial Area, State of Qatar 

​

Office hours: 8:00 AM - 5:00 PM

​​

Deputy Manager

murad@winwalldoha.com 

Tel: +974 500 73 800

​​

Technical Departement

technical@winwalldoha.com

Tel: +974 5019 2227 

​

Testing Departement

testing@winwalldoha.com 

Tel: +974 7776 4015 

​

Accounting Department: 

account@winwalldoha.com 

Tel: +974 5019 6668  

​

 Saudi Branch:

 

Address: Riyadh, Kingdom of Saudi Arabia 

​

Office hours: 8:00 AM - 5:00 PM

​​

Deputy Manager

murad@winwallsaudi.com â€‹

Tel: +966 56 403 8241, +974 5007 3800  

​

Testing Departement

testing@winwallsaudi.com 

 

​​

​

​

​

​

Egypt Branch:  

​

Address: 5 Baghdad St.

Korba Heliopolis, Cairo, Egypt

​

Office hours: 8:00 AM - 5:00 PM

​​

Deputy Manager

murad@winwallafrica.com 

Tel: +20 0106 8815281, +974 5007 3800 

​​

Testing Departement

testing@winwallafrica.com 

​

 â€‹

​

WNWALL DOHA ACCREDITATIONS  

Thanks for submitting!

SEND YOUR QUERIES TO US: 

© Wnwall Doha for Testing and Inspection 

  • gmail
  • Query
  • LinkedIn Social Icon
bottom of page